Weakly Supervised Multi-Label Knee MRI Abnormality Detection with ConvNeXt and Window-Attention MIL

Authors

  • Bajpayee Singha Master’s of Computer Science and Technology, School of Artificial Intelligence, Yanshan University, Qinhuangdao, China
  • Md. Sulayman B.Sc. in Electronic and Electrical Engineering, Department of Electrical and Electronic Engineering, Manarat International University, Dhaka, Bangladesh

DOI:

https://doi.org/10.54536/ajsts.v5i2.8870

Keywords:

ConvNeXt, Knee MRI, Multiple-Instance Learning, Multi-Label Classification, Weak Supervision

Abstract

Automated analysis of knee magnetic resonance imaging (MRI) is challenging because relevant abnormalities may be distributed across many slices, while comprehensive expert annotations are expensive to obtain. This study examines a weakly supervised multi-label framework combining a ConvNeXt-Small encoder, finding-specific spatial attention and window-attention multiple-instance learning (MIL). The supplied training archive contains 4,407 unique study identifiers and twelve report-derived target scores. Of these, 4,349 non-gold studies have complete soft-target values; 4,263 were included in the final all-data training pool, while 58 designated gold studies were excluded from training and 86 non-gold identifiers were absent from the frozen local image pool. MRI windows comprise three adjacent slices sampled at a nominal physical interval of 3.5 mm, with full-field and anatomy-centred local views. The recorded model was trained for 16 epochs using soft-target binary cross-entropy and AdamW optimisation. Training loss decreased from 0.55166 to 0.39110, a reduction of 29.1%. Descriptive analysis showed substantial variation in the frequency of target scores at or above 0.5, from 6.8% for fracture to 58.8% for effusion, and a strong correlation between effusion and synovitis scores (Spearman’s ρ = 0.903). At study level, 72.3% of studies had at least two scores ≥0.5; the largest fold-wise range in a target’s high-score proportion was 4.24 percentage points. These results describe the training labels and optimisation behaviour, not clinical diagnostic performance. The supplied checkpoint was trained on all eligible studies and has no held-out evaluation. Independent testing against appropriate reference labels is therefore required before diagnostic accuracy or clinical utility can be claimed.

Downloads

Download data is not yet available.

References

Bien, N., Rajpurkar, P., Ball, R. L., Irvin, J., Park, A., Jones, E., Bereket, M., Patel, B. N., Yeom, K. W., Shpanskaya, K., Halabi, S., Zucker, E., Amanatullah, D. F., Beaulieu, C. F., Riley, G. M., Stewart, R. J., Blankenberg, F. G., Larson, D. B., Jones, R. H., … Lungren, M. P. (2018). Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet. PLOS Medicine, 15(11), e1002699. https://doi.org/10.1371/journal.pmed.1002699

Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., & Kressel, H. Y. (2015). STARD 2015: An updated list of essential items for reporting diagnostic accuracy studies. BMJ, 351, h5527. https://doi.org/10.1136/bmj.h5527

Cai, L., Huang, S., Zhang, Y., Lu, J., & Zhang, Y. (2025). AttriMIL: Revisiting attention-based multiple instance learning for whole-slide pathological image classification from a perspective of instance attributes. Medical Image Analysis, 103, 103631. https://doi.org/10.1016/j.media.2025.103631

Collins, G. S., Moons, K. G. M., Dhiman, P., Riley, R. D., Beam, A. L., Van Calster, B., Ghassemi, M., Liu, X., Reitsma, J. B., van Smeden, M., Boulesteix, A.-L., Camaradou, J. C., Celi, L. A., Denaxas, S., Denniston, A. K., Glocker, B., Golub, R. M., Harvey, H., Heinze, G., … Logullo, P. (2024). TRIPOD+AI statement: Updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ, 385, e078378. https://doi.org/10.1136/bmj-2023-078378

DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988). Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach. Biometrics, 44(3), 837–845. https://doi.org/10.2307/2531595

Efron, B., & Tibshirani, R. J. (1993). An introduction to the bootstrap. Chapman & Hall.

Fawcett, T. (2006). An introduction to ROC analysis. Pattern Recognition Letters, 27(8), 861–874. https://doi.org/10.1016/j.patrec.2005.10.010

Gadermayr, M., & Tschuchnig, M. (2024). Multiple instance learning for digital pathology: A review of the state-of-the-art, limitations and future potential. Computerized Medical Imaging and Graphics, 112, 102337. https://doi.org/10.1016/j.compmedimag.2024.102337

Gill, S. S., Haq, T., Zhao, Y., Ristic, M., Amiras, D., & Gupte, C. M. (2026). AI demonstrates comparable diagnostic performance to radiologists in MRI detection of anterior cruciate ligament tears: A systematic review and meta-analysis. European Radiology, 36, 2500–2517. https://doi.org/10.1007/s00330-025-12020-2

Gitto, S., Serpi, F., Albano, D., Risoleo, G., Fusco, S., Messina, C., & Sconfienza, L. M. (2024). AI applications in musculoskeletal imaging: A narrative review. European Radiology Experimental, 8, Article 22. https://doi.org/10.1186/s41747-024-00422-8

Guermazi, A., Omoumi, P., Tordjman, M., Fritz, J., Kijowski, R., Regnard, N.-E., Carrino, J., Kahn, C. E., Knoll, F., Rueckert, D., Roemer, F. W., & Hayashi, D. (2024). How AI may transform musculoskeletal imaging. Radiology, 310(1), e230764. https://doi.org/10.1148/radiol.230764

Guo, C., Pleiss, G., Sun, Y., & Weinberger, K. Q. (2017). On calibration of modern neural networks. In Proceedings of the 34th International Conference on Machine Learning (pp. 1321–1330). PMLR.

He, K., Zhang, X., Ren, S., & Sun, J. (2016). Deep residual learning for image recognition. In Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (pp. 770–778). https://doi.org/10.1109/CVPR.2016.90

Ilse, M., Tomczak, J. M., & Welling, M. (2018). Attention-based deep multiple instance learning. In Proceedings of the 35th International Conference on Machine Learning (pp. 2127–2136). PMLR.

Irvin, J., Rajpurkar, P., Ko, M., Yu, Y., Ciurea-Ilcus, S., Chute, C., Marklund, H., Haghgoo, B., Ball, R., Shpanskaya, K., Seekins, J., Mong, D. A., Halabi, S. S., Sandberg, J. K., Jones, R., Larson, D. B., Langlotz, C. P., Patel, B. N., Lungren, M. P., & Ng, A. Y. (2019). CheXpert: A large chest radiograph dataset with uncertainty labels and expert comparison. Proceedings of the AAAI Conference on Artificial Intelligence, 33(1), 590–597. https://doi.org/10.1609/aaai.v33i01.3301590

Johnson, A. E. W., Pollard, T. J., Greenbaum, N. R., Lungren, M. P., Deng, C.-Y., Peng, Y., Lu, Z., Mark, R. G., Berkowitz, S. J., & Horng, S. (2019). MIMIC-CXR-JPG, a large publicly available database of labeled chest radiographs. Scientific Data, 6, Article 317. https://doi.org/10.1038/s41597-019-0322-0

Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019). Key challenges for delivering clinical impact with artificial intelligence. BMC Medicine, 17, Article 195. https://doi.org/10.1186/s12916-019-1426-2

Liu, Z., Mao, H., Wu, C.-Y., Feichtenhofer, C., Darrell, T., & Xie, S. (2022). A ConvNet for the 2020s. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (pp. 11976–11986). https://doi.org/10.1109/CVPR52688.2022.01167

Loshchilov, I., & Hutter, F. (2019). Decoupled weight decay regularization. In International Conference on Learning Representations.

Mead, K., Cross, T., Roger, G., Sabharwal, R., Singh, S., & Giannotti, N. (2025). MRI deep learning models for assisted diagnosis of knee pathologies: A systematic review. European Radiology, 35, 2457–2469. https://doi.org/10.1007/s00330-024-11105-8

Misera, L., Müller-Franzes, G., Truhn, D., & Kather, J. N. (2024). Weakly supervised deep learning in radiology. Radiology, 312(1), e232085. https://doi.org/10.1148/radiol.232085

Mohammadi, S., Jahanshahi, A., Shahrabi Farahani, M., Salehi, M. A., Frounchi, N., & Guermazi, A. (2025). Diagnosis of knee meniscal injuries using artificial intelligence: A systematic review and meta-analysis of diagnostic performance. PLOS ONE, 20(6), e0326339. https://doi.org/10.1371/journal.pone.0326339

Nagendran, M., Chen, Y., Lovejoy, C. A., Gordon, A. C., Komorowski, M., Harvey, H., Topol, E. J., Ioannidis, J. P. A., Collins, G. S., & Maruthappu, M. (2020). Artificial intelligence versus clinicians: Systematic review of design, reporting standards, and claims of deep learning studies. BMJ, 368, m689. https://doi.org/10.1136/bmj.m689

Ovadia, Y., Fertig, E., Ren, J., Nado, Z., Sculley, D., Nowozin, S., Dillon, J., Lakshminarayanan, B., & Snoek, J. (2019). Can you trust your model’s uncertainty? Evaluating predictive uncertainty under dataset shift. In Advances in Neural Information Processing Systems (Vol. 32).

Qiu, Z., Xie, Z., Lin, H., Li, Y., Ye, Q., Wang, M., Li, S., Zhao, Y., & Chen, H. (2024). Learning co-plane attention across MRI sequences for diagnosing twelve types of knee abnormalities. Nature Communications, 15, Article 7637. https://doi.org/10.1038/s41467-024-51888-4

Radiological Society of North America. (n.d.). RSNA Knee Abnormality Detection [Data set]. Kaggle. Retrieved October 21, 2026, from https://www.kaggle.com/competitions/rsna-knee-abnormality-detection/data

Roberts, M., Driggs, D., Thorpe, M., Gilbey, J., Yeung, M., Ursprung, S., Aviles-Rivero, A. I., Etmann, C., McCague, J., Beer, L., Weir-McCall, J. R., Teng, Z., Gkrania-Klotsas, E., AIX-COVNET, Rudd, J. H. F., Sala, E., Escudero Sánchez, L., Delgado Ortet, M., Martin Gonzalez, P., … Schönlieb, C.-B. (2021). Common pitfalls and recommendations for using machine learning to detect and prognosticate for COVID-19 using chest radiographs and CT scans. Nature Machine Intelligence, 3, 199–217. https://doi.org/10.1038/s42256-021-00307-0

Saito, T., & Rehmsmeier, M. (2015). The precision-recall plot is more informative than the ROC plot when evaluating binary classifiers on imbalanced datasets. PLOS ONE, 10(3), e0118432. https://doi.org/10.1371/journal.pone.0118432

Smit, A., Jain, S., Rajpurkar, P., Pareek, A., Ng, A. Y., & Lungren, M. P. (2020). CheXbert: Combining automatic labelers and expert annotations for accurate radiology report labeling using BERT. In Proceedings of the 2020 Conference on Empirical Methods in Natural Language Processing (pp. 1500–1519). Association for Computational Linguistics. https://doi.org/10.18653/v1/2020.emnlp-main.117

Sounderajah, V., Guni, A., Liu, X., Collins, G. S., Karthikesalingam, A., Markar, S. R., Golub, R. M., Denniston, A. K., Shetty, S., Moher, D., Bossuyt, P. M., Darzi, A., Ashrafian, H., & STARD-AI Steering Committee. (2025). The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence. Nature Medicine, 31, 3283–3289. https://doi.org/10.1038/s41591-025-03953-8

Tejani, A. S., Klontzas, M. E., Gatti, A. A., Mongan, J. T., Moy, L., Park, S. H., & Kahn, C. E., Jr. (2024). Checklist for Artificial Intelligence in Medical Imaging (CLAIM): 2024 update. Radiology: Artificial Intelligence, 6(4), e240300. https://doi.org/10.1148/ryai.240300

Varoquaux, G., & Cheplygina, V. (2022). Machine learning for medical imaging: Methodological failures and recommendations for the future. npj Digital Medicine, 5, Article 48. https://doi.org/10.1038/s41746-022-00592-y

Vaswani, A., Shazeer, N., Parmar, N., Uszkoreit, J., Jones, L., Gomez, A. N., Kaiser, Ł., & Polosukhin, A. (2017). Attention is all you need. In Advances in Neural Information Processing Systems (Vol. 30).

Xie, Z., Qiu, Z., Li, Y., Chen, X., Ye, Q., Wang, M., Chen, X., Shao, Y., Liu, C., Song, L., Lin, H., Li, S., Zhang, R., Li, T., Chen, L., Duan, Y., Li, C., Chen, H., & Zhao, Y. (2025). Development of a multi-task deep learning system for classification of nine common knee abnormalities on MRI: A large-scale, multicentre, stepwise validation study. eClinicalMedicine, 89, 103534. https://doi.org/10.1016/j.eclinm.2025.103534

Yang, Y., Zhang, H., Gichoya, J. W., Katabi, D., & Ghassemi, M. (2024). The limits of fair medical imaging AI in real-world generalization. Nature Medicine, 30, 2838–2848. https://doi.org/10.1038/s41591-024-03113-4

Zeng, X., Abdullah, N., & Sumari, P. (2024). Self-supervised learning framework application for medical image analysis: A review and summary. BioMedical Engineering OnLine, 23, Article 107. https://doi.org/10.1186/s12938-024-01299-9

Zhao, Y., Coppola, A., Karamchandani, U., Amiras, D., & Gupte, C. M. (2024). Artificial intelligence applied to magnetic resonance imaging reliably detects the presence, but not the location, of meniscus tears: A systematic review and meta-analysis. European Radiology, 34, 5954–5964. https://doi.org/10.1007/s00330-024-10625-7

Downloads

Published

2026-11-27

How to Cite

Sulayman, M. . (2026). Weakly Supervised Multi-Label Knee MRI Abnormality Detection with ConvNeXt and Window-Attention MIL. American Journal of Smart Technology and Solutions, 5(2), 227-241. https://doi.org/10.54536/ajsts.v5i2.8870